NAME OF INSTRUMENTS AND THEIR SPECIFICATION

About the Department
Conductivity  Meter – Desktop  Model
Conductivity Range     :  0 to 200 m MHO or m S
Measuring Accuracy    :  ± 1% of F.S. in all the ranges, ± 1 count.
Display                        :  2½ Digit Digital Panel Meter.
Conductivity cell              :  Approx 1.0 cell constant
Power Requirement    :  230 volt ± 10 %,50 Hz
Standard Accessories :  Conductivity Cell, Manual, Stand


About the Department
TDS Meter
   Frequency-1 kHz in built
   Weight- Approx- 1.5 Kg
   Environment- 5 to 50 Degree C
   Digital table top tds meter with 1. 0k cell with stand, rod, clmap
   Range: four selectable ranges 20ppm, 200ppm, 2ppt & 200ppt
   Resolution: 0. 01ppm, 0. 1ppm, 0. 001ppt & 0. 1ppt 
   Accuracy: ±1% of f. S. In all ranges ±1 digit   25°c 
   Frequency: 1khz in built 
   Display: 3. 5 digit, red led display with auto decimal 
   Selection calibration: single point manually 
   Cell: 1. 0 cell constant ± 10% (platinum cell) 
   Power requirement: 230v a. C ± 10%, 50hz single phase
   Dimension: 205 x 65 x 130mm ( aluminum powder coated cabinet )


About the Department
PH Meter  Desktop Model
Designed specially for taking accurate ph measurements with automatic temperature compensation with pt 100 probe and in chemical research laboratory & industries. " using high i/p  impedance pump & isi circuits ensures precision. The unit is operated with 230v ac mains. Regulated power supply ensures stable operation besides ph measurements. The unit can be used for measuring redox potential in its mv mode. Also slope control is provided for ph electrode deviation from the standard measuring modes.
pH Range                     :            0 to 14 Ph
Mv Range                     :            0 to 1999±1mv
Resolution                    :            0.01 pH, 1 mv   in mv range
Repeatability                 :            0.01 pH ±1 digit     , 1 mv ± 1 digit in std.  condition
Standardization Range :             Min. 2  pH.
Temp compensation     :             0 – 100°C             (Manual)
Display point                :             3½ digits LED with auto polarity & Decimal
Power                          :             230V ± 10%, 50 Hz


About the Department
Visible Photo-spectrometer
M/C BASED VISIBLE SPECTRO PHOTO METER WAVELENGTH
Range :   340 to 960 nm , Accuracy :   + 2 nm ,  Read out :   dial   ,    Bandwidth :   5.0 nm
PHOTOMETRIC
Range :   -0.3A.0 to 2.500 Abs     , Accuracy :  +  0.005 Abs at 1.0 A    ,  Resolution :  0.1 % T, 0.1001 Abs
Read out :  4 digit LED   ,    Grating :  600 lines /mm   ,     Source ;  Tungsten Halogen Lamp 12 V, 50 w
Detector :Silicon Photo diode, Measuring Mode :  1) % transmittance 2)  Absorbance 3) Concentration    4) K Factor
K factor Range :  0 to 9999 , Concentration range :  0 to 9999
Power :  230 V, 50 Hz  ,   Accessories : two 10 mm path length curettes and manual